Medical Infant Baby Incubator in Hospital
-
Price:
Negotiable
- minimum:
- Total supply:
-
Delivery term:
The date of payment from buyers deliver within days
-
seat:
Jiangsu
-
Validity to:
Long-term effective
-
Last update:
2017-12-28 14:50
-
Browse the number:
172
+
Zhangjiagang Yooda Medical Technology Co., Ltd.
- Contactaixin:
Mr. Carl(Mr.)
- Email: telephone: phone:
-
Arrea:
Jiangsu
Address:Yuanjiaqiao Village, Jingang Town, Zhangjiagang City, Suzhou, Jiangsu, China 215600
- Website:
+
medical hospital infant baby incubator
Brief Introduction:
Air mode control, set temperature and air temperature are displayed separately;
Natural air flow humidity
Failure alarm indication;
RS-232 connector
YD-YP100B are configured with fixed Neonate Bilirubin Phototherapy Equipment model: YD-XHZ-90 (with blue fluorescence lamps)
DC motor
Standard Configuration:
YD-YP100A: Based on YD-YP100 ,added with the side door
YD-YP100B: Based on YD-YP100A, added with the Neonate bilirubin phototherapy equipment (fixed model)
Optional Configuration:
>37°C temperature override mode fundation, Baby mode, Configured with fixed neonate bilirubin phototherapy equipment model: YDXHZ-90L (with LED blue light) and SPO2
Specification:
Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA
Mode of control: Air mode control by micro-computer
Air temperature control range: 25°C -37°C (override mode: 37°C -39°C is optional)
The temperature difference between incubator temperature and average incubator temperature(under steady temperature condition)≤0.5°C
Temperature uniformity≤0.8°C
Noise inside hood: 45dB(A)
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, fan motor alarm, power failure alarm, system alarm and so on.
Environmental temperature:
Operating range: 20 °C -30°C (Set temperature should be higher 3°C than the environment temperature)
Ambient air movement rate: < 0.3m/s
Package
Brief Introduction:
Air mode control, set temperature and air temperature are displayed separately;
Natural air flow humidity
Failure alarm indication;
RS-232 connector
YD-YP100B are configured with fixed Neonate Bilirubin Phototherapy Equipment model: YD-XHZ-90 (with blue fluorescence lamps)
DC motor
Standard Configuration:
YD-YP100A: Based on YD-YP100 ,added with the side door
YD-YP100B: Based on YD-YP100A, added with the Neonate bilirubin phototherapy equipment (fixed model)
Optional Configuration:
>37°C temperature override mode fundation, Baby mode, Configured with fixed neonate bilirubin phototherapy equipment model: YDXHZ-90L (with LED blue light) and SPO2
Specification:
Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA
Mode of control: Air mode control by micro-computer
Air temperature control range: 25°C -37°C (override mode: 37°C -39°C is optional)
The temperature difference between incubator temperature and average incubator temperature(under steady temperature condition)≤0.5°C
Temperature uniformity≤0.8°C
Noise inside hood: 45dB(A)
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, fan motor alarm, power failure alarm, system alarm and so on.
Environmental temperature:
Operating range: 20 °C -30°C (Set temperature should be higher 3°C than the environment temperature)
Ambient air movement rate: < 0.3m/s
Package
Package | each unit is packed into one carton |
Dimension | 1085mm x 640mm x 1075mm |
Gross Weight | 83kg |